This case reviews a bladder mass-like finding in a 39-year-old woman examined with CHISON SonoMax. Grayscale and color Doppler imaging document the bladder anatomy, volume and a left ureteric jet, illustrating why an apparent mass must be assessed alongside catheter-related structures.
Patient: 39-year-old woman
Examination: Transabdominal bladder ultrasound
System: CHISON SonoMax
Modes: Two-dimensional grayscale ultrasound and color Doppler imaging
Adequate bladder filling provides an acoustic window for evaluating the bladder wall and lumen. B mode in ultrasound produces the grayscale images used to assess structure, echogenicity and the relationship of a finding to the bladder wall. [5]

Figure 1. Grayscale ultrasound of the bladder.
The bladder is well distended, with an anechoic lumen and a clearly visualized wall. Grayscale imaging shows a rounded structure of intermediate echogenicity near the posterior bladder, projecting into the lumen with relatively defined margins. Its origin requires correlation with additional views and the catheter balloon shown in Figure 3.

Figure 2. Bladder dimensions and system-estimated volume.
The recorded bladder dimensions are 8.46 × 8.92 × 9.31 cm. The system-estimated bladder volume is 367.96 mL. These measurements describe the bladder, rather than the mass-like structure.

Figure 3. Color Doppler views showing a left ureteric jet and an intravesical catheter balloon.
A urinary catheter balloon is visible within the bladder. A jet-like color signal extends into the lumen near the left ureterovesical junction, consistent with a left ureteric jet. This signal represents urine flow and does not establish vascularity within the mass-like structure. [4]
A focal intravesical structure may represent a bladder lesion or a mimic such as a blood clot, stone, fungal ball, foreign body or catheter-related structure. Evaluate its origin, wall attachment, mobility, echogenicity, acoustic shadowing and Doppler findings before characterizing it. [5]
Finding | Typical ultrasound appearance | Key distinguishing features |
Bladder tumor | Often attached to the bladder wall; may project into the lumen | Assess the attachment, wall relationship, shape and vascularity |
Blood clot | Mass-like or irregular echoes | Usually no internal flow; may move with a change in position |
Bladder stone | Typically hyperechoic | Posterior acoustic shadowing and mobility are useful clues |
Fungal ball | Rounded or mass-like echoes | Assess mobility and the relevant clinical history |
Foreign body or iatrogenic structure | Appearance depends on the material or device | Correlate with procedural history and real-time scanning |
Figure 4. Original differential diagnosis chart. English translation below.
The images document bladder distension, a mass-like appearance, a catheter balloon and a left ureteric jet. Multi-plane, real-time assessment is needed to establish whether a separate bladder-wall lesion is present. Ultrasound can identify and describe a suspicious structure, but a definitive tumor diagnosis requires appropriate urological assessment and histological confirmation. [1,2]
CHISON SonoMax combines grayscale imaging, bladder volume measurement and color Doppler information to support a structured bladder ultrasound examination.
For educational use. Clinical interpretation requires the full examination and patient history.
1. European Association of Urology. EAU Guidelines on Non-muscle-invasive Bladder Cancer. Diagnosis. 2026. https://uroweb.org/guidelines/non-muscle-invasive-bladder-cancer/chapter/diagnosis
2. European Association of Urology. EAU Guidelines on Muscle-invasive and Metastatic Bladder Cancer. Diagnostic Evaluation. https://uroweb.org/guidelines/muscle-invasive-and-metastatic-bladder-cancer/chapter/diagnostic-evaluation
3. Imaging of Bladder Cancer: Standard Applications and Future Trends. Medicina. 2021;57(3):220. doi:10.3390/medicina57030220.
4. Leung VYF, Chu WCW, Yeung CK, Metreweli C. Doppler waveforms of the ureteric jet: an overview and implications for the presence of a functional sphincter at the vesicoureteric junction. Pediatr Radiol. 2007;37:417–425. doi:10.1007/s00247-007-0433-1.
5. Smereczyński A, Szopiński T, Gołąbek T, Ostasz O, Bojko S. Sonography of tumors and tumor-like lesions that mimic carcinoma of the urinary bladder. J Ultrason. 2014;14:36–48. doi:10.15557/JoU.2014.0004.
Contact Us
Copyright © CHISON Medical Technologies Co., Ltd. All Rights Reserved | Privacy and terms of use
Products: Vascular Ultrasound Machine MSK Ultrasound Machine Portable Ultrasound Device Portable Ultrasound Machine for Sale Portable Ultrasound Machines For Pregnancy Handheld Ultrasound For Pregnancy Handheld Veterinary Ultrasound Veterinary Ultrasound Machine Portable Vascular Ultrasound Portable Ultrasound Machine for Cattle and Livestock

CHISON respects your privacy. We use cookies to make our site more personal and enhance your experience. Read our Private Policy to learn more about cookies and how to manage them. You agree to our use of these technologies when you visit our site.

We appreciate your feedback
We sincerely invite you to participate in our survey for helping us to improve our digital market.
*1.How fast does the website load?
*2.Does the products displayed on the website interest you?
*3.How easy is it for you to find the information you need?
4.What information or service do you suggest we can offer?

THANKS
Thank you for sharing your thoughts with us. We’re highly appreciated your every feedback.

Sorry!

THANKS
Thank you for sharing your thoughts with us. We’re highly appreciated your every feedback.